Thermo-mass flowmeter Specifications: Linear signal output:0-5 VDC &4-20 mA Signal Interface: RS232 &RS485 Accuracy,including linearity(Ref:21℃):±【1% of Reading +( .5%+.02%/℃ of Full Scale)】 Repeatability:±0.2% of Full Scale Sensor response time:1 second Turn down ratio:100:1 minimum Electronics temperature range:0°-50℃(32°-122℉),extended temperature optional Gas temperature range:-40°-200℃(-40°-392℉),extended range available Gas pressure effect:Negligible over ±20% of absolute calibration pressure Pressure rating maximum:500 PSI Std.,>500 PSI special Input power requirement: 24VDC @250mA 115 VAC 50/60 Hz optional 230 VAC 50/60 Hz optional Flow Transmitter power requirements:5 watts maximum Wetted materials:316 Stainless Steel(Hastelloy and Monel optional) Standard temperature &pressure(STP):70℉ & 29.92″Hg(Air 0075 lb./cubic foot) NIST traceable calibration: Standard |